Initializing a data item with a value of the wrong type will lead to runtime errors. The rule checks that numeric data items are not initialized
with alphanumeric/alphabetic values and that alphanumeric /alphabetic data items are not initialized with numeric values.
Noncompliant code example
       WORKING-STORAGE SECTION.
         EJECT
       01  TAB-POS.
           02  FILLER  PIC A(14) VALUE 0.  *> Noncompliant
           02  FILLER  PIC 9(14) VALUE 'ASDFJKL;QWERTY'.  *> Noncompliant
       01 MYGROUP PIC 9(1).
          88 X VALUE 1,2.
          88 Y VALUE 3, "BLUE".  *> Noncompliant; BLUE is alphanumeric
Compliant solution
       WORKING-STORAGE SECTION.
         EJECT
       01  TAB-POS.
           02  FILLER  PIC A(14)  VALUE 'ASDFJKL;QWERTY'.
           02  FILLER  PIC 9(14)  VALUE 0.
       01 MYGROUP PIC 9(1).
          88 X VALUE 1,2.
          88 Y VALUE 3, 4.